Open Access

Table 1

Grid independence verification results for a nozzle diameter of 450 μm

Number Number of grids Inlet pressure/kPa Inlet mass flow rate/(g·min-1)
1 355 628 5.70 50
2 420 195 5.84 50
3 505 655 5.88 50
4 603 678 5.91 50
5 658 535 5.93 50
6 775 748 5.94 50
7 857 561 5.95 50
8 1 036 549 5.95 50
9 1 200 137 5.96 50