Open Access
Table 1
Description of TEP faults
Fault ID | Description | Type |
---|---|---|
0 | Normal state | None |
1 | Material A/C feed ratio changes, material B does not change | Step |
2 | Material B changes, A/C feed ratio does not change | Step |
3 | Material D temperature change | Step |
4 | Reactor cooling water inlet temperature change | Step |
5 | Condenser cooling water temperature change | Step |
6 | Material A feed loss | Step |
7 | Material C pressure loss | Random variation |
8 | The composition of materials A, B, and C changes | Random variation |
9 | Material D temperature change | Random variation |
10 | Material C temperature change | Random variation |
11 | Reactor cooling water inlet temperature change | Random variation |
12 | Condenser cooling water inlet temperature change | Random variation |
13 | Reaction kinetics change | Slowly drift |
14 | Reactor cooling water valve sticking | Sticking |
15 | Condenser cooling water valve sticking | Sticking |
16-20 | Unknown | Unknown |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.